彩钢板广泛用于建筑,家电和交通运输等行业,对于建筑业主要用于钢结构厂房、机场、车间,活动房,箱房,净化车间,库房和冷冻等工业及商业建筑的屋顶墙面和门等,民用建筑采用彩钢板的较少。彩钢板的安装很有技术性的,没有经验的公司根本不知道怎么安装彩钢板才能达到要求,这里济南彩钢板就根据多年施工老师的经验,为大家简单的介绍一下彩钢板的安装要求,希望对各位有所帮助。

Color steel plate is widely used in construction, home appliances, transportation and other industries. For the construction industry, it is mainly used in steel structure workshop, airport, workshop, activity room, box room, purification workshop, warehouse, freezing and other industrial and commercial buildings, such as roof walls and doors, while less color steel plate is used in civil buildings. The installation of color steel plate is very technical. Companies without experience don't know how to install color steel plate to meet the requirements. Here Jinan color steel introduces the installation requirements of color steel plate according to the experience of many years of construction teachers, hoping to help you.

彩钢板安装要求:

Installation requirements of color steel plate:

一、场地核实

1、 Site verification

1.在洁净地面上初次处理之后,设备定位。按设备定位、设计图纸对隔墙放线定位,确定现场尺寸是否与图纸尺寸、设备位置有相冲突的地方;

  1. After the first treatment on the clean ground, the equipment should be positioned. According to the equipment positioning and design drawings, set out and position the partition wall to determine whether the site size conflicts with the drawing size and equipment location;

    2-2105291G104615.jpg

2.对现场地面的水平进行核实,看波动是否较大,是否有必要对彩钢板墙体底部整体校平。

2. Verify the level of the ground to see if the fluctuation is large, and whether it is necessary to level the bottom of the color steel plate wall as a whole.

二、安装要求

2、 Installation requirements

1.内外圆弧固定:与彩钢板连接一定要严实,外圆弧立柱不驳接,内圆弧连接点之间不错位,缝隙严实。

1. Internal and external arc fixation: the connection with color steel plate must be tight, the external arc column shall not be connected, the internal arc connection points shall not be dislocated, and the gap shall be tight.

2.每一块顶板与围护板之间的固定一定有3颗钻尾螺丝,围护板、立板之间连接处上下各有一颗拉钉固定,边施工边固定,板缝一定垂直;

2. There must be three tail drilling screws between each roof and the enclosure, and a pull screw at the upper and lower joints between the enclosure and the vertical plate. The plate joints must be vertical while the construction is in progress;

3.T型吊梁固定:吊码沿放线位置定位,间距不超过1.20m,T型梁与连接彩钢板固定时一定用角铝或角铁压紧,不得留有空隙,压固体一定在两块彩钢板连接缝之上;

3. Fixation of T-shaped lifting beam: the lifting code shall be positioned along the setting out position, and the spacing shall not exceed 1.20m. When fixing the T-shaped beam and the connecting color steel plate, the angle aluminum or angle iron must be used to compress the T-shaped beam, and no gap shall be left. The pressing solid must be on the joint of two color steel plates;

4.槽铝固定:固定槽铝前一定先放线定位,偏差不能超过5mm,槽铝用M5x30抽心铝拉钉固定,间接不超过300mm,有门洞位置须设置双拉钉,间隔不超过50mm;

4. Fixing of channel aluminum: before fixing the channel aluminum, the setting out and positioning must be carried out, and the deviation shall not exceed 5mm. The channel aluminum shall be fixed with m5x30 core pulling aluminum nail, and the indirect distance shall not exceed 300 mm. Double pulling nails shall be set at the position with door opening, and the interval shall not exceed 50 mm;

5.风口安装:天花上的风口安装要按图纸施工,避开T型梁。墙体上的排、回风口安装要离地200mm;

5. Installation of air outlet: the installation of air outlet on the ceiling shall be carried out according to the drawing, avoiding T-beam. The air outlet and return outlet on the wall shall be installed 200 mm above the ground;

6.外观要求:整体安装需平直美观,不得有碰撞刮划痕迹,要到才能撕保护膜,板缝连接平实,板缝间距3-4mm,打胶要满缝平直,不得有缝隙;

6. Appearance requirements: the overall installation shall be straight and beautiful, without collision and scratch marks, the protective film can be torn only after reaching the surface, the plate seam connection shall be smooth, the plate seam spacing shall be 3-4mm, and the gluing shall be full seam and straight, without gaps;

7.门窗安装:门窗的安装位置和开启方向按图纸要求而定,单开门尽量在同一块彩钢板上,双 开门的中 心线尽量在板缝连接处,以便切下的彩钢板做门板,门窗的型材连接需严密,不能有缝隙,整体门拐留置尺寸一定统一;

7. Installation of doors and windows: the installation position and opening direction of doors and windows shall be determined according to the requirements of the drawing. The single door shall be on the same color steel plate as far as possible, and the center line of double door shall be at the joint of plate seam as far as possible, so that the cut color steel plate can be used as the door plate. The profile connection of doors and windows shall be tight without gaps, and the overall size of the door shall be uniform;

以上是济南彩钢板给大家整理的彩钢板安装要求和规范,无论是场地还是安装时的一些注意事项都给大家整理出来了,想要了解更多精彩内容可以直接关注http://www.jnhxtcg.com

The above are the installation requirements and specifications of Jinan color steel plate, and some precautions of both site and installation are sorted out. If you want to know more wonderful content, you can pay attention to it directly http://www.jnhxtcg.com